
OpenAlex is a bibliographic catalogue of scientific papers, authors and institutions accessible in open access mode, named after the Library of Alexandria. It's citation coverage is excellent and I hope you will find utility in this listing of citing articles!
If you click the article title, you'll navigate to the article, as listed in CrossRef. If you click the Open Access links, you'll navigate to the "best Open Access location". Clicking the citation count will open this listing for that article. Lastly at the bottom of the page, you'll find basic pagination options.
Requested Article:
Diagnostic Image Quality of a Low-Field (0.55T) Knee MRI Protocol Using Deep Learning Image Reconstruction Compared with a Standard (1.5T) Knee MRI Protocol
Ingo Schmidt, Nina Haag, Iram Shahzadi, et al.
Journal of Clinical Medicine (2023) Vol. 12, Iss. 5, pp. 1916-1916
Open Access | Times Cited: 18
Ingo Schmidt, Nina Haag, Iram Shahzadi, et al.
Journal of Clinical Medicine (2023) Vol. 12, Iss. 5, pp. 1916-1916
Open Access | Times Cited: 18
Showing 18 citing articles:
Environmental Sustainability and MRI : Challenges, Opportunities, and a Call for Action
Yuri V. Chaban, Jan Vosshenrich, Hayley McKee, et al.
Journal of Magnetic Resonance Imaging (2023) Vol. 59, Iss. 4, pp. 1149-1167
Open Access | Times Cited: 48
Yuri V. Chaban, Jan Vosshenrich, Hayley McKee, et al.
Journal of Magnetic Resonance Imaging (2023) Vol. 59, Iss. 4, pp. 1149-1167
Open Access | Times Cited: 48
A perspective on the evolution of semi-quantitative MRI assessment of osteoarthritis: Past, present and future
Frank W. Roemer, Mohamed Jarraya, Daichi Hayashi, et al.
Osteoarthritis and Cartilage (2024) Vol. 32, Iss. 4, pp. 460-472
Open Access | Times Cited: 10
Frank W. Roemer, Mohamed Jarraya, Daichi Hayashi, et al.
Osteoarthritis and Cartilage (2024) Vol. 32, Iss. 4, pp. 460-472
Open Access | Times Cited: 10
Comparing Metal Artifact Severity and Ability to Assess Near-Metal Anatomy Between 0.55 T and 1.5 T MRI in Patients with Metallic Spinal Implants—A Scanner Comparison Study
Alina Carolin Seifert, Hanns‐Christian Breit, Felix Schlicht, et al.
Academic Radiology (2024) Vol. 31, Iss. 6, pp. 2456-2463
Closed Access | Times Cited: 6
Alina Carolin Seifert, Hanns‐Christian Breit, Felix Schlicht, et al.
Academic Radiology (2024) Vol. 31, Iss. 6, pp. 2456-2463
Closed Access | Times Cited: 6
The scientific evidence of commercial AI products for MRI acceleration: a systematic review
Stefan J. Fransen, Christian Roest, Frank F.J. Simonis, et al.
European Radiology (2025)
Open Access
Stefan J. Fransen, Christian Roest, Frank F.J. Simonis, et al.
European Radiology (2025)
Open Access
Metal Suppression Magnetic Resonance Imaging Techniques in Orthopaedic and Spine Surgery
Katharina Ziegeler, Daehyun Yoon, Mari Hoff, et al.
Journal of the American Academy of Orthopaedic Surgeons (2025)
Closed Access
Katharina Ziegeler, Daehyun Yoon, Mari Hoff, et al.
Journal of the American Academy of Orthopaedic Surgeons (2025)
Closed Access
Imaging near titanium total hip arthroplasty at 0.55 T compared with 3 T
Kübra Keskin, Sophia Cui, Bochao Li, et al.
Magnetic Resonance in Medicine (2025)
Open Access
Kübra Keskin, Sophia Cui, Bochao Li, et al.
Magnetic Resonance in Medicine (2025)
Open Access
Generating Synthetic T2*-Weighted Gradient Echo Images of the Knee with an Open-source Deep Learning Model
Konstantinos Vrettos, Evangelia E. Vassalou, Grigoria Vamvakerou, et al.
Academic Radiology (2025)
Closed Access
Konstantinos Vrettos, Evangelia E. Vassalou, Grigoria Vamvakerou, et al.
Academic Radiology (2025)
Closed Access
Comparison of image quality and diagnostic efficacy of routine clinical lumbar spine imaging at 0.55T and 1.5/3T
Anna Lavrova, Nicole Seiberlich, Lauren Kelsey, et al.
European Journal of Radiology (2024) Vol. 175, pp. 111406-111406
Closed Access | Times Cited: 3
Anna Lavrova, Nicole Seiberlich, Lauren Kelsey, et al.
European Journal of Radiology (2024) Vol. 175, pp. 111406-111406
Closed Access | Times Cited: 3
New clinical opportunities of low-field MRI: heart, lung, body, and musculoskeletal
Ye Tian, Krishna S. Nayak
Magnetic Resonance Materials in Physics Biology and Medicine (2023) Vol. 37, Iss. 1, pp. 1-14
Open Access | Times Cited: 6
Ye Tian, Krishna S. Nayak
Magnetic Resonance Materials in Physics Biology and Medicine (2023) Vol. 37, Iss. 1, pp. 1-14
Open Access | Times Cited: 6
Does bore size matter?—A comparison of the subjective perception of patient comfort during low field (0.55 Tesla) and standard (1.5 Tesla) MRI imaging
Arwed Elias Michael, Andreas Heuser, Christoph Moenninghoff, et al.
Medicine (2023) Vol. 102, Iss. 47, pp. e36069-e36069
Open Access | Times Cited: 5
Arwed Elias Michael, Andreas Heuser, Christoph Moenninghoff, et al.
Medicine (2023) Vol. 102, Iss. 47, pp. e36069-e36069
Open Access | Times Cited: 5
Deep Learning Reconstructed New-Generation 0.55 T MRI of the Knee—A Prospective Comparison With Conventional 3 T MRI
Ricardo Donners, Jan Vosshenrich, Magdalena Seng, et al.
Investigative Radiology (2024)
Closed Access | Times Cited: 1
Ricardo Donners, Jan Vosshenrich, Magdalena Seng, et al.
Investigative Radiology (2024)
Closed Access | Times Cited: 1
New-Generation 0.55 T MRI of the Knee—Initial Clinical Experience and Comparison With 3 T MRI
Ricardo Donners, Jan Vosshenrich, Andreas Gutzeit, et al.
Investigative Radiology (2023)
Open Access | Times Cited: 3
Ricardo Donners, Jan Vosshenrich, Andreas Gutzeit, et al.
Investigative Radiology (2023)
Open Access | Times Cited: 3
Research Studies Evaluating Image Quality on Commercial 0.55 T MRI Systems Are Essential for Sequence Optimization and Appropriate Clinical Deployment
Nicole Seiberlich
Academic Radiology (2023) Vol. 30, Iss. 11, pp. 2447-2449
Closed Access | Times Cited: 2
Nicole Seiberlich
Academic Radiology (2023) Vol. 30, Iss. 11, pp. 2447-2449
Closed Access | Times Cited: 2
Improved liver fat and R2* quantification at 0.55 T using locally low‐rank denoising
Shu‐Fu Shih, Bilal Taşdelen, Ecrin Yağız, et al.
Magnetic Resonance in Medicine (2024)
Open Access
Shu‐Fu Shih, Bilal Taşdelen, Ecrin Yağız, et al.
Magnetic Resonance in Medicine (2024)
Open Access
Enhancement of Image Quality in Low-Field Knee MR Imaging Using Deep Learning
Tsutomu Inaoka, Akihiko Wada, Masayuki Sugeta, et al.
Cureus (2024)
Open Access
Tsutomu Inaoka, Akihiko Wada, Masayuki Sugeta, et al.
Cureus (2024)
Open Access
Current MR imaging of cartilage in the context of knee osteoarthritis (part 1)
Teresa Lemainque, Marc Huppertz, Can Yüksel, et al.
Deleted Journal (2023) Vol. 64, Iss. 4, pp. 295-303
Closed Access | Times Cited: 1
Teresa Lemainque, Marc Huppertz, Can Yüksel, et al.
Deleted Journal (2023) Vol. 64, Iss. 4, pp. 295-303
Closed Access | Times Cited: 1
[MRI] 3. Current Status of AI Image Reconstruction in Clinical MRI Systems
Shinya Kojima
Japanese Journal of Radiological Technology (2023) Vol. 79, Iss. 10, pp. 1200-1209
Closed Access
Shinya Kojima
Japanese Journal of Radiological Technology (2023) Vol. 79, Iss. 10, pp. 1200-1209
Closed Access
Preoperative and Postoperative Imaging and Outcome Scores for Osteochondral Lesion Repair of the Ankle
Loek D. Loozen, Alastair Younger, Andrea Veljkovic
Foot and Ankle Clinics (2023) Vol. 29, Iss. 2, pp. 235-252
Closed Access
Loek D. Loozen, Alastair Younger, Andrea Veljkovic
Foot and Ankle Clinics (2023) Vol. 29, Iss. 2, pp. 235-252
Closed Access